Safety Light Curtain Fault

SAF-001

Safety light curtain reports internal fault or alignment error. Machine is locked out until fault is cleared.

critical general packaging palletizer conveyor
safety light curtain alignment lockout

Probable Causes (ranked)

Fix Steps

  1. 1 Clean both emitter and receiver lenses with soft dry cloth
  2. 2 Check alignment indicators on both units — must show aligned
  3. 3 Realign units if needed — follow manufacturer alignment procedure
  4. 4 Inspect cables for damage — especially at connector and flex points
  5. 5 Shield from external light sources if interference suspected
  6. 6 If internal fault, replace the faulted unit (emitter or receiver)

Field Trick

Most light curtain faults are dirty lenses or misalignment from vibration. Clean first, realign second, replace last.