Shrink Tunnel — Temperature Fault / Uneven Shrink

PKG-SHRINK1

Shrink tunnel producing uneven, incomplete, or excessive shrink on products. Film is not conforming uniformly to the product contour.

medium packaging
packaging shrink tunnel temperature heater film pvc

Probable Causes (ranked)

Fix Steps

  1. 1 Check tunnel temperature at multiple points — use a thermocouple probe at the inlet, middle, and outlet
  2. 2 Verify heater elements are all functioning — measure resistance on each element
  3. 3 Check circulation fans — all should be running at full speed during operation
  4. 4 Adjust conveyor speed through the tunnel — slower speed = more heat exposure = tighter shrink
  5. 5 Verify film type matches the tunnel temperature setting — PVC: 275-325F, polyolefin: 300-375F
  6. 6 Check for air leaks at tunnel inlet and outlet — curtains or air curtains should minimize heat escape

Field Trick

If one side of the product shrinks tight and the other side is loose, the problem is the upstream wrapper, not the tunnel. The loose side has too much film, so even though it shrinks, there's excess material that bunches up. Fix the wrapper so film distribution is even, then the tunnel produces uniform shrink.