Compressed Air System Low Pressure

GEN-CMP1

Plant compressed air pressure below minimum operating threshold. Pneumatic equipment may malfunction or stop.

high general packaging palletizer
compressed air pneumatic compressor pressure leak

Probable Causes (ranked)

Fix Steps

  1. 1 Check compressor status — restart if safe to do so
  2. 2 Walk the air line and listen for leaks — mark and repair
  3. 3 Check main pressure gauge at compressor discharge — should be 100-125 PSI
  4. 4 Verify air dryer is cycling — check dew point indicator
  5. 5 Check automatic drain valves — stuck open drains bleed pressure fast
  6. 6 If demand exceeds capacity, stagger pneumatic equipment startup
  7. 7 Check main header regulator — set to plant spec (typically 80-90 PSI downstream)

Field Trick

Shut down all pneumatic equipment on a weekend and watch the compressor. If it cycles on frequently with nothing running, you have a major leak to find.