RepairXpert Industrial Automation

Packaging Machine Seal Fault

70002

Heat seal bar temperature or pressure out of specification. Packages may have incomplete seals.

medium packaging
packaging seal heater temperature

Probable Causes (ranked)

Fix Steps

  1. 1 Check seal bar temperature with IR thermometer — compare to controller display reading
  2. 2 Inspect heater element — measure resistance with multimeter, compare to nameplate
  3. 3 Verify air supply pressure to seal cylinder — minimum 80 PSI required
  4. 4 Clean seal bar surfaces — remove film buildup carefully with brass brush or scraper
  5. 5 If heater was recently replaced, run auto-tune on temperature controller
  6. 6 Replace thermocouple if temperature reading is erratic or significantly different from IR reading

Suggested Replacement Parts

Parts matched to fault category: Thermocouple

Type K Thermocouple Probe 6 inch P/N: TC-K-NPT-U-72 Type K, 1/4 NPT, ungrounded, 6 inch length, -200 to 1250C
Type J Thermocouple Probe 6 inch P/N: TC-J-NPT-U-72 Type J, 1/4 NPT, ungrounded, 6 inch, -210 to 760C

Prices are estimates. Verify part numbers match your equipment before ordering.