RepairXpert Industrial Automation

VFD Fault — Overvoltage

50002

VFD DC bus voltage exceeded safe threshold, typically during deceleration when motor regenerates energy back to drive.

high conveyor piler packaging palletizer
vfd drive overvoltage braking deceleration

Probable Causes (ranked)

Fix Steps

  1. 1 Increase deceleration ramp time in VFD parameters — try doubling current setting
  2. 2 Check dynamic braking resistor — measure resistance with multimeter, verify wiring
  3. 3 Measure incoming AC voltage at VFD input terminals — should be within drive rating
  4. 4 Enable coast-to-stop mode for high-inertia loads if application allows it
  5. 5 Check VFD braking transistor output — consult drive manual for test procedure